TF1
Absolute position transducers for high dynamic positioning tasks. Inductive measurement principle, touchless position detection with free position markers; unlimited mechanical life
> Messbereich max. : 1000 mm
> Schnittstelle : Spannung, Strom, IO-Link, SSI, CANopen,
> Schutzart min. : IP67
> Temperatur : -40° C bis 85° C
TP1
Absolute position transducers in robust profile design; NOVOSTRICTIVE non-contacting, magnetostrictive measurement principle, non-contact position detection with free position markers; unlimited mechanical life
> Messbereich max. : 4250 mm
> Schnittstelle : Spannung, Strom, IO-Link, SSI, CANopen, Inkremental, Start-Stop,
> Schutzart min. : IP67, IP68
> Temperatur : -40° C bis 85° C
TH1
Absolute rod style position transducer for integration in cylinders. NOVOSTRICTIVE - non-contacting, magnetostrictive measurement principle; non-contact position detection with ring position marker.
> Messbereich max. : 4250 mm
> Schnittstelle : Spannung, Strom, IO-Link, SSI, CANopen, Start-Stop,
> Schutzart min. : IP67, IP68
> Temperatur : -40° C bis 85° C
TM1 with Plug-in Flange
Absolute rod style position transducer for integration in cylinders especially for mobile applications; NOVOSTRICTIVE non-contacting, magnetostrictive measurement principle; non-contact position detection with ring-shaped position marker; unlimited mechanical life
> Messbereich max. : 2000 mm
> Schnittstelle : Spannung, Strom, CANopen, CAN SAE J1939,
> Schutzart min. : IP67, IP69
> Temperatur : -40° C bis 105° C
TM1 with Screw Flange
Absolute rod style position transducer for integration in cylinders especially for mobile applications; NOVOSTRICTIVE non-contacting, magnetostrictive measurement principle; non-contact position detection with ring-shaped position marker; unlimited mechanical life
> Messbereich max. : 2000 mm
> Schnittstelle : Spannung, Strom, CANopen, CAN SAE J1939,
> Schutzart min. : IP67
> Temperatur : -40° C bis 105° C
LS1 transducer
Absolute transducer in compact profile design with double-sided supported actuating rod; NOVOPAD non-contating, inductive measurement principle; Teach-in function with status LEDs; ball coupling for backlash- and shear force free operation , long life
> Messbereich max. : 200 mm
> Schnittstelle : Spannung, Strom,
> Schutzart min. : IP40
> Temperatur : -40° C bis 100° C
LS1 with Return Spring
Absolute transducer in compact profile design with double-sided supported actuating rod and internal return spring; NOVOPAD non-contacting, inductive measuring principle, Teach-in function with status LEDs, probe tip with pressed-in hardened metal ball, long life
> Messbereich max. : 100 mm
> Schnittstelle : Spannung, Strom,
> Schutzart min. : IP40
> Temperatur : -40° C bis 100° C
TFD-4000
Absolute position transducers in compact, flat design. Non-contacting NOVOHALL measuring principle; Touchless position detection with position marker; Unlimited mechanical life
> Messbereich max. : 50 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP67, IP68, IP69
> Temperatur : -40° C bis 125° C
FTI
Absolute precision transducer with central mounting, durable because contactless measurement; completely encapsulated by a robust housing, temperature-resistant precision due to supplementary regulation winding
> Messbereich max. : 10 mm
> Schnittstelle : Strom,
> Schutzart min. : IP50, IP67
> Temperatur : -25° C bis 70° C
F200
Absolute, inductive transducer with centering collar, integrated sealed hybrid electronic, DC power supply; floating DC voltage output, good temperature stability, maintenance-free plastic plain bearings and bellows; long long life
> Messbereich max. : 20 mm
> Schnittstelle : Spannung,
> Schutzart min. : IP67
> Temperatur : -30° C bis 70° C
TE1 with Return Spring
Absolut transducer with integrated signal processing. Designed for direct position measurement of fixed objects or contour scanning of moving objects by roller head. Replaceable without new calibration.
> Messbereich max. : 100 mm
> Schnittstelle : Spannung, Strom,
> Schutzart min. : IP40
> Temperatur : -40° C bis 85° C
T / TS
Absolut transducer with integrated signal processing. Designed for direct position measurement of fixed objects or contour scanning of moving objects by roller head. Replaceable without new calibration.
> Messbereich max. : 150 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP40
> Temperatur : -30° C bis 100° C
TR / TRS with Return Spring
Absolut transducer with integrated signal processing. Designed for direct position measurement of fixed objects or contour scanning of moving objects by roller head. Replaceable without new calibration.
> Messbereich max. : 100 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP40
> Temperatur : -30° C bis 100° C
TX2 Pivot Head Mounting
Potentiometric, absolut position transducer with double supported actuating rod; long life and high adjustement speed; decoupled wiper tap; easy to assemble via low-backlash pivot heads with a large angle of freedom; High protection class
> Messbereich max. : 300 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP67
> Temperatur : -40° C bis 100° C
TX2 with Mounting Clamp
Potentiometric, absolut position transducer; robust design with metal flanges and pressure equalization system with GORE-membran; long life and high adjustement speed; easy to assemble via low-backlash pivot heads with a large angle of freedom; High protection class
> Messbereich max. : 300 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP67
> Temperatur : -40° C bis 100° C
TEX Rod Type
Potentiometric, absolut position transducer; pendular fixed slide bearing and decoupled wiper tap for stick-slip-free movement; long life and high adjustement speed; easy to assemble via snap in and all side mountable clamps
> Messbereich max. : 300 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP54
> Temperatur : -40° C bis 85° C
TEX with Return Spring
Potentiometric, absolut position transducer without actuating rod with lengthwise coupling for reduced overall dimensions; metal wiper carrier; shear force free linkage via ball coupling; long life
> Messbereich max. : 200 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP54
> Temperatur : -40° C bis 85° C
TEX Pivot Head Mounting
Potentiometric , absolut position transducer; robust design with metal flanges, pressure equalization system, GORE-membran and an additional guard tube for the actuating rod; long life and high adjustement speed; easy to assemble via low-backlash pivot heads with a large angle of freedom; High protection class
> Messbereich max. : 300 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP54
> Temperatur : -40° C bis 85° C
LWG
Potentiometric, absolut position transducer with double supported actuating rod; long life and high adjustement speed; decoupled wiper tap; easy to assemble via low-backlash pivot heads with a large angle of freedom; High protection class
> Messbereich max. : 750 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP65
> Temperatur : -30° C bis 100° C
LWX-003
Potentiometric, absolut position transducer; robust design with metal flanges and pressure equalization system with GORE-membran; long life and high adjustement speed; easy to assemble via low-backlash pivot heads with a large angle of freedom; High protection class
> Messbereich max. : 750 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP67
> Temperatur : -30° C bis 100° C
LWX-004, Shaft Protected
Potentiometric , absolut position transducer; robust design with metal flanges, pressure equalization system, GORE-membran and an additional guard tube for the actuating rod; long life and high adjustement speed; easy to assemble via low-backlash pivot heads with a large angle of freedom; High protection class
> Messbereich max. : 750 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP67
> Temperatur : -30° C bis 100° C
LWH
Potentiometric, absolut position transducer; pendular fixed slide bearing and decoupled wiper tap for stick-slip-free movement; long life and high adjustement speed; easy to assemble via snap in and all side mountable clamps
> Messbereich max. : 900 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP55
> Temperatur : -30° C bis 100° C
TLH
Potentiometric, absolut position transducer without actuating rod with lengthwise coupling for reduced overall dimensions; metal wiper carrier; shear force free linkage via ball coupling; long life
> Messbereich max. : 3000 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP40, IP54
> Temperatur : -30° C bis 100° C
PTP
Absolute, potentiometric position transducer in cost-optimized compact design; open housing for mounting in closed devices; variable mechanical customer interface; basic version for customized solutions
> Messbereich max. : 300 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP00
> Temperatur : -40° C bis 100° C
PTN
Absolute, potentiometric resistance elements and wiper; for mounting in closed devices; customized solutions with laser-linearization, switch function and redundancy technically feasible
> Messbereich max. : 250 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP00
> Temperatur : -40° C bis 100° C
PTX
Absolute, potentiometric resistance elements and wiper; for mounting in closed devices; customized solutions with laser-linearization, switch function and redundancy technically feasible
> Messbereich max. : 300 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP00
> Temperatur : -40° C bis 100° C
LFP
Product discontinued - Replacement requirement on request! Potentiometric resistive elements with foil collector and mechanical pressure pin. Hermetically bonded structure. Handling is very simple since the sensitive potentiometer track is protected by the cover sheet.
> Messbereich max. : 500 mm
> Schnittstelle : Ratiometrisch,
> Schutzart min. : IP67