Navigation überspringen
zur Startseite (Novotechnik)
Series
  • TF1
  • TP1
  • TH1
  • TIM with plug-in flange
  • TIM with screw flange
  • LS1 Transducer
  • LS1 Transducer with return spring
  • FTI
  • F200
  • TE1 Transducer
  • TE1 Transducer with return spring
  • T / TS Transducer
  • TR / TRS Transducer with return spring
  • TEX pivot head mounting
  • TEX Transducer with actuating rod
  • TEX Transducer with return spring
  • TX2 pivot head mounting
  • TX2 with mounting clamp
  • LWG
  • LWX-003
  • LWX-004, shaft protected
  • LWH
  • TLH
  • PTP
  • PTN
  • PTX
  • LFP
Technology
  • Induktiv
  • Magnetostriktiv
  • Potentiometrisch
Interface
  • Analog
  • SSI
  • CANopen
  • IO-Link
  • Start-Stop
  • Incremental
  • ratiometrisch
Protection min.
  • all
  • from IP00
  • from IP6K9K
  • from IP6k7
  • from IP40
  • from IP50
  • from IP54
  • from IP55
  • from IP65
  • from IP67
  • from IP68
  • from IP69k
Temperature min.
  • all
  • from -40°C
  • from -30°C
  • from -25°C
  • from 0°C
Temperature max.
  • all
  • from 70°C
  • from 85°C
  • from 100°C
  • from 105°C
  • from 120°C
  • from 125°C

Option selected

Current selection: none
39 product(s) found

TF1

Absolute position transducers for high dynamic positioning tasks. Inductive measurement principle, touchless position detection with free position markers; unlimited mechanical life span

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
1000 mm Analog
IP67
-25° C 85° C
1000 mm SSI
IP67
-25° C 85° C
1000 mm CANopen
IP67
-25° C 85° C
1000 mm IO-Link
IP67
-25° C 85° C

TP1

Absolute position transducers in robust profile design; NOVOSTRICTIVE non-contacting, magnetostrictive measurement principle, non-contact position detection with free position markers; unlimited mechanical life span

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
4250 mm Analog
IP67
IP68
-40° C 85° C
4250 mm Start-Stop
IP67
IP68
-40° C 85° C
4250 mm SSI
IP67
IP68
-40° C 85° C
4250 mm Incremental
IP67
IP68
-40° C 85° C
4250 mm CANopen
IP67
IP68
-40° C 85° C

TH1

Absolute rod style position transducer for integration in cylinders. NOVOSTRICTIVE - non-contacting, magnetostrictive measurement principle; non-contact position detection with ring position marker.

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
4250 mm Analog
IP67
IP68
-40° C 85° C
4250 mm Start-Stop
IP67
IP68
-40° C 85° C
4250 mm SSI
IP67
IP68
-40° C 85° C
4250 mm CANopen
IP67
IP68
-40° C 85° C

TIM with plug-in flange

Absolute rod style position transducer for integration in cylinders especially for mobile applications ; NOVOSTRICTIVE non-contacting, magnetostrictive measurement principle; non-contact position detection with ring position marker; unlimited mechanical life span

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
2500 mm Analog
IP67
IP69k
-40° C 105° C
2500 mm CANopen
IP67
IP69k
-40° C 105° C

TIM with screw flange

(Product discontinued. Replaced by series TH1). Absolute rod style position transducer for integration in cylinders especially for mobile applications ; NOVOSTRICTIVE non-contacting, magnetostrictive measurement principle; non-contact position detection with ring position marker; unlimited mechanical life span

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
2500 mm Analog
IP67
-40° C 105° C
2500 mm CANopen
IP67
-40° C 105° C

LS1 Transducer

Absolute transducer in compact profile design with double-sided supported actuating rod; NOVOPAD non-contating, inductive measurement principle; Teach-in function with status LEDs; ball coupling for backlash- and shear force free operation , long life span

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
200 mm Analog
IP40
-40° C 100° C

LS1 Transducer with return spring

Absolute transducer in compact profile design with double-sided supported actuating rod and internal return spring; NOVOPAD non-contacting, inductive measuring principle, Teach-in function with status LEDs, probe tip with pressed-in hardened metal ball, long life span

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
100 mm Analog
IP40
-40° C 100° C

FTI

Absolute precision transducer with central mounting, durable because contactless measurement; completely encapsulated by a robust housing, temperature-resistant precision due to supplementary regulation winding

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
10 mm Analog
IP50
IP67
-25° C 70° C

F200

Inductive transducer with centering collar, integrated sealed hybrid electronic, DC power supply; floating DC voltage output, good temperature stability, maintenance-free plastic plain bearings and bellows; long long life

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
20 mm Analog
IP67
-30° C 70° C

TE1 Transducer

Absolut transducer for precise measuring and control applications with integrated signal processing. Replaceable without new calibration.

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
150 mm Analog
IP40
-40° C 85° C

TE1 Transducer with return spring

Absolut transducer with integrated signal processing. Designed for direct position measurement of fixed objects or contour scanning of moving objects by roller head. Replaceable without new calibration.

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
100 mm Analog
IP40
-40° C 85° C

T / TS Transducer

Potentiometric position transducer in compact profile design with double-sided supported actuating rod; very high repeatability and adjustement speed; ball coupling for backlash- and shear force free operation , long life span

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
150 mm ratiometrisch
IP40
-30° C 100° C

TR / TRS Transducer with return spring

Potentiometric position transducer in compact profile design with double-sided supported actuating rod and internal return spring; very high repeatability and adjustement speed; probe tip with pressed-in hardened metal ball, long life span

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
100 mm ratiometrisch
IP40
-30° C 100° C

TEX pivot head mounting

Potentiometric position transducer in compact design with one-sided actuating rod; long life span and high adjustement speed; easy to assemble via low-backlash pivot heads with a large angle of freedom

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
300 mm ratiometrisch
IP54
-40° C 85° C

TEX Transducer with actuating rod

Potentiometric position transducer in compact design with one-sided actuating rod; long life span and high adjustement speed; Flexible mounting via clamps, bushing mounts or flange plates

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
300 mm ratiometrisch
IP54
-40° C 85° C

TEX Transducer with return spring

Potentiometric position transducer in compact design with one-sided actuating rod and return spring; long life span and high adjustement speed; Flexible mounting via clamps, bushing mount or flange plates; probe tip with pressed-in hardened metal ball

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
200 mm ratiometrisch
IP54
-40° C 85° C

TX2 pivot head mounting

Potentiometric position transducer with very compact dimensions; robust design with metal flanges; sintered bronze plain bearing; long life span and high adjustement speed; easy to assemble via low-backlash pivot heads with a large angle of freedom; High protection class

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
300 mm ratiometrisch
IP67
-40° C 100° C

TX2 with mounting clamp

Potentiometric position transducer with very compact dimensions; robust design with metal flanges; sintered bronze plain bearing; long life span and high adjustement speed; easy to assemble via sliding metal mounting clamps; High protection class

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
300 mm ratiometrisch
IP67
-40° C 100° C

LWG

Potentiometric position transducer with double supported actuating rod; long life span and high adjustement speed; decoupled wiper tap; easy to assemble via low-backlash pivot heads with a large angle of freedom; High protection class

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
750 mm ratiometrisch
IP65
-30° C 100° C

LWX-003

Potentiometric position transducer; robust design with metal flanges and pressure equalization system with GORE-membran; long life span and high adjustement speed; easy to assemble via low-backlash pivot heads with a large angle of freedom; High protection class

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
750 mm ratiometrisch
IP67
-30° C 100° C

LWX-004, shaft protected

Potentiometric position transducer; robust design with metal flanges, pressure equalization system, GORE-membran and an additional guard tube for the actuating rod; long life span and high adjustement speed; easy to assemble via low-backlash pivot heads with a large angle of freedom; High protection class

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
750 mm ratiometrisch
IP67
-30° C 100° C

LWH

Potentiometric position transducer; pendular fixed slide bearing and decoupled wiper tap for stick-slip-free movement; long life span and high adjustement speed; easy to assemble via snap in and all side mountable clamps

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
900 mm ratiometrisch
IP55
-30° C 100° C

TLH

Potentiometric position transducer without actuating rod with lengthwise coupling for reduced overall dimensions; metal wiper carrier; shear force free linkage via ball coupling; long life span

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
3000 mm ratiometrisch
IP40
IP54
-30° C 100° C

PTP

Potentiometric position transducer in cost-optimized compact design; open housing for mounting in closed devices; variable mechanical customer interface; basic version for customized solutions

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
300 mm ratiometrisch
IP00
-40° C 100° C

PTN

Potentiometric resistance elements and wiper; for mounting in closed devices; customized solutions with laser-linearization, switch function and redundancy technically feasible

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
250 mm ratiometrisch
IP00
-40° C 100° C

PTX

Potentiometric resistance elements and wiper; for mounting in closed devices; customized solutions with laser-linearization, switch function and redundancy technically feasible

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
300 mm ratiometrisch
IP00
-40° C 100° C

LFP

Potentiometric resistive elements with foil collector and mechanical pressure pin. Hermetically bonded structure. Handling is very simple since the sensitive potentiometer track is protected by the cover sheet.

Range max. Interface Protection min. Temp. min. Temp. max. Data sheet Remember
500 mm ratiometrisch
IP67
-40° C 125° C
Nach oben